Detail E

– Manually Close Curtain


To set the Limit Switches, locate the Lock Motor Control Box. See Detail C. NOTE: Items noted
in brackets [ ] in this section can be found in Detail B.

1. Unscrew the limit Switch Cover and locate the Allen Wrench and the hex

shaft packaged in the Vinyl Storage Seal. See Detail D.


2. Remove the Vinyl Storage Seal and locate the six Hex Adjusting Screws on

the Ring Screws. See Detail E.

















3. Run the curtains to the bottom position by using a Crank or Drill [Item 14

Detail B] or by manually turning the one of the three Left Adjusting Screws
with the Allen Wrench from the Vinyl Seal as illustrated in Detail E. NOTE:
If turning the drive with drill and adaptor, run to end position carefully (very
slowly). Maximum drive speed is 1400 rpm.

NOTE: Electrical power must be applied and Limit Switches must be properly
wired for curtains to operate by moving the Setting Rings.

4. With the curtain at the bottom limit, turn the Left Limit Switch’s 3

Setting Rings until the Limit Switch Roller [22] snaps into place in the
Switch Groove [21]. See Detail F.















































Limit Switch
Cover removed

Allen wrench
for adjusting
Limit Switches

Hex shaft for
manually
rotating motor

Vinyl

Storage

Seal

Detail D

– Remove Limit Switch Cover

Detail C

– Lock Motor

Lock Motor

Limit Switch

Cover

Curtain Moves Down