Cpd,vrs: vrs assumption mode – Spectra Precision ProMark 800 Reference Manual User Manual

Page 187

Advertising
background image

175

Set Command Library

Example

Resetting the RTK processing:

$PASHS,CPD,RST*5B

Relevant Query

Command

None.

CPD,VRS: VRS Assumption Mode

Function

This command is used specifically to set the receiver (a rover)
to operate in the so-called “compulsory VRS mode” through
which it is forced to consider that the differential corrections
it receives are always VRS corrections (this impacts the way
corrections are processed internally).

When not operated in this mode, the receiver will
automatically detect whether the received corrections are, or
are not, VRS corrections (Automatic detection).

Command Format

Syntax

$PASHS,CPD,VRS,d[*cc]

Parameters

Example

Enabling the compulsory VRS mode:

$PASHS,CPD,VRS,1*44

Comment

Users working in VRS using the CMR or RT2 format should
activate the compulsory VRS mode (d=1).

Relevant Query

Command

$PASHQ,CPD,VRS

Parameter

Description

Range

Default

d

VRS assumption mode:
• 0: Automatic detection
• 1: Compulsory VRS mode
• 2: Never switches to VRS mode

0, 1, 2

0

*cc

Optional checksum

*00-*FF