Examples – Spectra Precision ProMark 800 Reference Manual User Manual

Page 278

Advertising
background image

266

Query Command Library

Parameters

Examples

Data recording disabled:

$PASHQ,ATL*2E
$PASHR,ATL,OFF,0,S,1,0*2C

Data recording enabled and in progress:

$PASHQ,ATL*2E
$PASHR,ATL,ON,0,R,0.5,0*79

Data recording is enabled but for some reason (no SD card,
etc.), no data is being recorded:

$PASHQ,ATL*2E
$PASHR,ATL,ON,0,S,0.5,0*78

Parameter

Description

Range

s1

ON/OFF/AUT status:
• ON: Debug data recording is enabled

but will not re-start after a power cycle.

• OFF: Debug data recording is disabled.
• AUT: Debug data recording is enabled

and will re-start after a power cycle.

ON, OFF, AUT

d2

Indicates which data are recorded:
• 0: Only data from GNSS board to sys-

tem board are recorded.

• 1: Only data from system board to

GNSS board are recorded.

• 2: Data flowing in both directions are

recorded.

0-2

c3

Recording status:
• R: The receiver is currently recording

data for debugging.

• S: No debug data currently recorded.

R, S

f4

Output rate, in seconds (default: 1 sec.)

0.05, 0.1, 0.2,0.5, 1

d5

Configuration index

0, 1

*cc

Checksum

*00-*FF