345
Query Command Library
Parameters
Relevant Set
Command
$PASHS,RAW
RCP: Receiver Parameters
Function
Command Format
Syntax
Parameter
Description
Range
PER
Output rate, in seconds
0.00-999.00
ELM
Elevation mask used in data recording &
data output
0-90
RAW
Raw data type
MPC, DPC, PBN,
SNV, SNG, SNW,
SAL, SAG, SAW,
ION, SBD
PRTA
Serial port
ON, OFF
PRTC
Bluetooth
ON, OFF
MEMM
MEMU
Labels for memories M (MEMM: internal
memory) and U (MEMU: USB key)
ON-OFF
BAUD
For serial port: Baud rate code
For other devices, “0” if not available, else
“1”
0-15 (see table
below)
Code
Baud Rate
Code
Baud Rate
0
300
7
38400
1
600
8
57600
2
1200
9
115200
3
2400
10
230400
4
4800
11
460800
5
9600
12
921600
6
19200
13
1428571