Qzs: enabling/disabling qzss tracking, Command format, Relevant query command – Spectra Precision ProMark 800 Reference Manual User Manual
Page 230: Function

218
Set Command Library
Command Format
Syntax
$PASHS,PWR,PAR,f1,f2[*cc]
Parameters
Example
Setting the thresholds to respectively 7 and 9 V:
$PASHS,PWR,PAR,7,9*41
Relevant Query
Command
$PASHQ,PWR
QZS: Enabling/Disabling QZSS Tracking
Function
This command is used to enable or disable QZSS tracking.
The QZSS constellation tracking function is off by default.
Command Format
Syntax
$PASHS,QZS,s[*cc]
Parameters
Example
Enabling QZSS tracking:
$PASHS,QZS,ON
Relevant Query
Command
$PASHQ,QZS
$PASHQ,PAR
Parameter
Description
Range
Default
f1
Battery voltage threshold, in volts, trigger-
ing a low-battery alarm
6.7-8.4
6.8
f2
External power voltage threshold, in volts,
triggering a low-power alarm
9.0-28.0
9.1
*cc
Optional checksum
*00-*FF
-
Parameter
Description
Range
Default
s
Programmable pin ID:
• ON: QZSS satellites tracked and used
• OFF: QZSS satellites not tracked
ON or OFF OFF
*cc
Optional checksum
*00-*FF