Raw,all: disabling all raw data messages, Raw,per: setting unique output rate for raw data – Spectra Precision ProMark 800 Reference Manual User Manual
Page 233

221
Set Command Library
See also
$PASHS,RAW,PER
$PASHS,RAW,ALL
$PASHS,POP
RAW,ALL: Disabling All Raw Data Messages
Function
This command is used to disable all the currently active raw
data messages on the specified port.
Command Format
Syntax
$PASHS,RAW,ALL,c1,OFF[*cc]
Parameters
Example
Disabling all raw data messages on port A:
$PASHS,RAW,ALL,A,OFF*52
Relevant Query
Command
None.
See Also
$PASHS,RAW
RAW,PER: Setting Unique Output Rate for Raw Data
Function
This command is used to set the same output rate for raw
data messages MPC, DPC and PBN. This command will
overwrite the output rates set individually for each of these
message types using $PASHS,RAW,xxx. Setting this rate does
not affect the data recording rate (set with $PASHS,DRI).
Parameter
Description
Range
c1
Port ID
• Serial port: ABluetooth port: C
• Memory: M, U
*cc
Optional checksum
*00-*FF