5. Thread a 1 in. female PVC adapter (not

included) onto the 1 in. x 5 in. nipple. Hand

tighten, then tighten 1 turn with a pipe wrench.

5

6

6. Using a two step PVC system (not included)

attach enough couplings and rigid PVC pipe

(not included) to the adapters to equal the

depth of the well minus 5 ft.

7. Before sliding the pipe assembly into the well,

firmly clamp the assembly with a pipe clamp

(not included) to prevent the assembly from

sliding down into the well.

7

8

8. Remove the pipe clamp and slide well seal

over the PVC pipes and onto the well casing.

The PVC pipe should extend approximately

12 in. from the well seal, depending on the

height of the pump.

NOTE: Do not let assembly slide down into well.

Tighten the well seal until rubber gaskets are tight

against the well casing and the PVC pipes.

IL1545

1 in. female

PVC adapter

1 in. x 5 in.

nipple

IL1546

Pipe clamp

40 ft.

maximum

Water level

5 ft.

minimum

12 in.

PVC Pipes

Well Seal

Well Casing

Well TO pUMp CONNeCTiON (SUCTiON pipe)