95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

1

1 in. Discharge Tee

1. wrap thread tape (not included) around

threads of a 1 in. discharge tee (not included).

Using a pipe wrench, thread the 1 in.

discharge tee into the top of pump.

NOTE: To improve performance and consistency,

a flow control (not included) is recommended

for deep well applications in place of a standard

discharge tee. This will help regulate water

pressure fluctuations and may prevent loss of

prime.

pUMp TO TANk CONNeCTiON (DiSCHARGe pipe)

2. Connect a 1 in. MPT x 1/4 in. FPT galvanized

bushing and pressure gauge (both not

included) or a pipe plug (not included) to the

discharge tee. Do not tighten, as you will

prime pump later at this location.

Pressure gauge

or pipe plug with

bushing

Discharge Tee

2

3. wrap thread tape around the threads of a

1 in. male PVC adapter (not included) and

thread the adapter into the discharge tee.

4. Continue with fittings and pipe to the

pressure tank. a 1 in. union is optional but

recommended for easy connection and

disconnection.

1 in. male

PVC adapter

Discharge

tee

3

1 in. union

To pressure

tank