TROUBleSHOOTiNG

pROBleM

pOSSiBle CAUSe

CORReCTiVe ACTiON

Little or no

discharge.

1. Pump is not primed.

1. Follow priming instructions (page 17).

2. Suction lift too high or too long.

2. Move pump closer to water source.

Lift should be less than 25 ft. for

shallow well installations and less

than 40 ft. for deep well installations.

3. Hole or air leak in suction line.

3. Repair or replace. Use pipe tape and

pipe sealing compound.

4. Foot valve too small.

4. Match foot valve to piping or install

one size larger foot valve.

5. Foot valve or suction line not

submerged deep enough in water.

5. Submerge lower in water.

6. Voltage switch incorrect.

6. Be sure 115 V or 230 V power supply

matches voltage switch setting on

pump.

7. Casing gasket leaking.

7. Replace.

Pump will not

deliver water

or develop

pressure.

1. Pump is not primed.

1. Follow priming instructions (page 17).

2. Leak in suction line.

2. Repair or replace. Pipe dope all

threads.

3. Discharge line is closed and priming

air has nowhere to go.

3. Open several outlets or faucets

during priming procedure.

4. Foot valve is leaking.

4. Replace foot valve.

5. Foot valve not submerged below

water level.

5. Lower foot valve and reprime.

Pump vibrates

and/or makes

excessive

noise.

1. Mounting plate or foundation not rigid

enough.

1. Reinforce.

2. Foreign material in pump.

2. Disassemble pump and clean.

3. Impeller damaged.

3. Replace.

Pump will not

start or run.

1. Voltage switch incorrect.

1. Be sure 115 V or 230 V power supply

matches voltage switch setting on

motor.

2. Blown fuse or open circuit breaker.

2. Replace fuse or close circuit breaker.

3. Loose or broken wiring.

3. Tighten connections, replace broken

wiring.

4. Stone or foreign object lodged in

impeller.

4. Disassemble pump and remove

foreign object.

5. Thermal overload has opened circuit. 5. allow unit to cool, restart after reason

for overload has been determined.