Star Water Systems SJ10 User Manual

Page 2

Advertising
background image

2

95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

TABle OF CONTeNTS

Product Specifications ......................................................................................................................2

Safety Information ............................................................................................................................2

Package Contents ............................................................................................................................4

Preparation .......................................................................................................................................5

General Pump Information ...............................................................................................................5

well to Pump Connection .................................................................................................................7

Pump to Tank Connection ..............................................................................................................13

Tank to House Connection .............................................................................................................14

Pump Electrical Connections..........................................................................................................15

Pump Priming and Startup .............................................................................................................17

Care and Maintenance ...................................................................................................................19

Troubleshooting ..............................................................................................................................20

warranty .........................................................................................................................................21

Replacement Parts .........................................................................................................................22

pRODUCT SpeCiFiCATiONS

Power supply required ...........................................................................115 volts or 230 volts, 60 Hz
(Pump is set by the factory to run on 230 volts)
Maximum water temperature ...........................................................................................77°F (25°C)
Individual branch circuit required ............................................................................15 amp minimum
Discharge connection ..........................................................................................................1 in. NPT
Suction connection ........................................................................................................1-1/4 in. NPT
Motor duty..................... Continuous duty with enforced air cooling and thermal overload protection
Pressure switch ...........................................................................Preset at 20 PSI “on” / 40 PSI “off”
water depth rating ................................................................................................. Maximum of 40 ft.

iTeM #

Hp

VOlTAGe HZ

AMp

CApACiTY - U.S. GAllONS peR MiNUTe

AT 20 pSi DiSCHARGe pReSSURe (pSi)

SHAllOW Well

Deep Well

5 FT.

15 FT.

25 FT.

30 FT.

40 FT.

SJ05

1/2

115/230

60

8.0/3.9

8.5

6.0

3.5

7.0

6.5

SJ07

3/4

115/230

60

10.9/5.4

10.0

8.0

4.5

8.5

6.8

SJ10

1

115/230

60

10.9/5.4

13.0

10.0

5.5

10.0

7.0