Glue to house plumbing from pump shut off valve – Star Water Systems SJ10 User Manual

Page 15

Advertising
background image

15

95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

TANk TO HOUSe CONNeCTiON

5. attach the pipe from the pump to the tee

installed in Step 4. Then, from the tee,

install 3/4 in. pipe and optional shut off

valve (not included) to connect tee to

house plumbing.

IL1369

Glue

To House

Plumbing

From Pump

Shut off valve

5

pUMp eleCTRiCAl CONNeCTiONS

WiRe SiZe CHART

Distance

from Motor to

Meter

Recommended Copper wire

and Fuse Sizes

Single Phase Motors

1/2 HP

3/4 HP

1 HP

115

Volt

230

Volt

115

Volt

230

Volt

115

Volt

230

Volt

0-50 Ft.

50-100 Ft.

100-150 Ft.

150-200 Ft.

200-300 Ft.

14

12

12

12

10

14

14

14

14

14

14

12

10

10

8

14

14

12

12

10

12

12

10

8

6

14

14

12

12

10

Fuse Size

(amps)

15

15

15

15

20

15

WARNiNG:

• always disconnect pump from electricity before

performing any work on the motor.

• Under-sized wiring can cause motor failure and even

fire. Use proper wire size specified in the Wire Size

Chart.

• Replace damaged or worn wiring cord immediately.

• Do not kink power cable and never allow the cable

to come in contact with oil, grease, hot surfaces, or

chemicals.

• The pump must be properly grounded using the proper

wire cable with ground.

CAUTiON:

• Protect the power cable from coming in contact with

sharp objects.

• All wiring should be performed by a qualified electrician in accordance with the National

Electric Code and local electric codes.

• Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Refer to the

wire Size Chart for proper fuse size.

6.

iMpORTANT: air pressure in the tank

must be 2 PSI lower than the “cut-in” of

the pressure switch. Pump has a 20/40

PSI pressure switch, so tank pressure

must be set at 18 PSI. Locate the air

valve/stem on the tank and check

pressure with a tire gauge (not included).

If air needs to be removed, press down on

valve to bleed off air. Use a tire pump or

air compressor to add air if needed.

Tire gauge

Tank

Air Valve/Stem

6

Advertising
This manual is related to the following products: