Star Water Systems SJ10 User Manual

Page 5

Advertising
background image

5

95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

2

GeNeRAl pUMp iNFORMATiON

pRepARATiON

Before beginning installation of product, make sure all parts are present. If any part is missing or

damaged, do not attempt to assemble the product. Compare parts to package contents list and

hardware contents list.
Estimated Installation Time: 2 hours.
Tools Required for assembly (not included): pipe wrench, pliers, Phillips screwdriver, pipe clamp, 2-step

PVC glue system (primer and sealer), thread tape
Parts Required for assembly (not included):

1-1/4 in. to 1 in. male PVC adapter, 1-1/4 in. male PVC

adapter, 1 in. male PVC adapter, 1 in. foot valve, 1-1/4 in. PVC pipe, 1 in. PVC pipe, 1-1/4 in. PVC

elbow, 1 in. PVC elbow, 1 in. discharge tee, galvanized bushing, pressure gauge or pipe plug, electrical

wire strain relief (2), 1 in. close nipple, 1 in. x 5 in. pipe nipple

Typical pump Setup

Convertible jet pumps are designed for use in

these applications:

1. Shallow wells (0 - 25 ft. lift) where ejector bolts

to pump.

2. Deep wells (0 -

40 ft. lift) where well inside

diameter is 4 in. or more and ejector is

installed in the well.

1

Discharge

to

Home

Water Level

1-1/4 in. Foot Valve

1 in.

Discharge Pipe

1 in.

Suction Pipe

Suction

Lift

25 ft.

Max.

1-1/4 in. x 1 in. Male Adapter

Discharge

to

Home

Water Level

1-1/4 in. Foot Valve

1 in.

Discharge Pipe

1-1/4 in.

Suction Pipe

Suction

Lift

40 ft.

Max.

1 in.

Pressure Pipe

1 -1/4 in. to 1 in. Male Adapter

1 in. Pipe

Advertising