Star Water Systems SJ10 User Manual

Page 19

Advertising
background image

19

95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

iMpORTANT: If pump fails to prime within five minutes:

Turn power off at the breaker box and check all pipe connections for leaks. all connections must be

water and air tight in order for pump to operate.

pUMp pRiMiNG AND STARTUp

Discharge

to

Home

Water Level

1-1/4 in. Foot Valve

1 in.

Discharge Pipe

1-1/4 in.

Suction Pipe

Suction

Lift

40 ft.

Max.

1 in.

Pressure Pipe

1 -1/4 in. to 1 in. Male Adapter

1 in. Pipe

7. Check suction pipe for any sagging. Support

suction pipe in a straight line to the pump.

NOTe: Look for leaks or a milky color in the

discharged water, which indicates an air leak.

Re-prime if necessary, following steps 1 through

6 above. Reset breaker at the breaker box. all

connections must be water and air tight in order

for pump to operate.

7

CARe AND MAiNTeNANCe
Winterizing

CAUTiON: Drain the entire system if

there is danger of freezing.

1. To drain pump, remove the drain plug

located on the front of pump and the priming

plug located on the top of pump.

Priming

Plug

Drain

Plug

1

Advertising