Well TO pUMp CONNeCTiON (SUCTiON pipe)

7b

IL1538

7b. Tighten bolts (aa) securely.
NOTE: The 1-1/4 in. opening in back of ejector

goes on top of pump and the 1 in. opening goes

on the bottom.

1 in. Male

PVC adapter

8. wrap thread tape around the threads of a 1 in.

male PVC adapter (not included). Thread the

adapter into the front of ejector.

9

IL1540

1 in. PVC Pipe

1 in. Male PVC

Adapter

Well

9. Using 2-step PVC system, attach 1 in. PVC

pipe and couplings (not included) as needed to

connect the 1 in. male PVC adapter to the 1 in.

PVC elbow attached to the top of the well pipe

in Step 5.

NOTE: Be sure the pipe slopes downward slightly

from pump to the well to prevent air pockets.

Proceed to

pUMp TO TANk CONNeCTiON