Shallow Well installations Only

1. Thread 1-1/4 in. male x 1 in. PVC adapter

(not included) into a 1-1/4 in. foot valve (not

included). Hand tighten, then tighten 1/2 turn

with a pipe wrench.

CAUTiON: Dry-fit entire assembly to ensure proper fit before gluing or taping parts.

CAUTiON: Follow all proper gluing procedures as specified by the glue manufacturer. Always

glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings

CAUTiON: Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to

a snug fit and add another 1/4 turn to ensure proper seal.

1

1-1/4 in. male x 1 in.

PVC adapter

1-1/4 in. foot valve

Well TO pUMp CONNeCTiON (SUCTiON pipe)

3. Before sliding the pipe assembly into the

well, firmly clamp the assembly with a pipe

clamp (not included) to prevent the assembly

from sliding down into the well.

2. Using a 2-step PVC system (not included),

attach enough PVC pipe and couplings to

the adapter to equal the depth of the well,

minus 5 ft.

2

3

1 in. PVC pipe

Pipe clamp

25 ft. maximum

Water level

5 ft. minimum