95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

pUMp eleCTRiCAl CONNeCTiONS

IL1376

Wire from

motor

Pressure

Switch

Strain

Relief

Wiring the pressure switch

1.

CAUTiON: Make certain that the power

source matches the pump requirements. This

pump has a dual voltage motor and can run

on 115 V or 230 V. This pump is pre-set at the

factory to run on 230 V.

NOTE: To change pump voltage, remove the

square voltage switch cover at the top of pump

and move the voltage switch as shown.

1

115 V

Setting

230 V

Setting

2

Wire from

motor

Wire from

power

supply

Wire from

motor

Wire from

power

supply

Outside

terminal

Outside

terminal

3

4

2. Insert an electrical wire strain relief into the

opening in the side of the pressure switch.

3. Thread the cable from the power supply

through the strain relief and tighten both

screws on the strain relief. Do not crush wire.

4. Connect the two wires from the power supply

to the two outside terminals on the pressure

switch.

Voltage swtich

cover

Advertising