Breaker box – Star Water Systems SJ10 User Manual

Page 18

Advertising
background image

18

95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

pUMp pRiMiNG AND STARTUp

4. Check to be sure water in the cavity of pump

stays constant. If water level goes down, it

could indicate a leak in the foot valve, check

valve or suction pipe.

Water

Level

Check for

Leaks

4

5. Once pump is filled, wrap the discharge tee

plug and priming plug threads with thread

tape and thread into pump. Tighten with

wrench.

NOTE: Before turning on breaker, open several

outlets or faucets to allow water flow during

priming.

Priming plug

or pressure

gauge

Vent plug

5

20

20

20

20

IL1339

Breaker Box

6. Turn on breaker to start pump.

iMpORTANT: If the pump hums instead of

pumping or turns off repeatedly, shut pump off

immediately.

Check voltage. Make sure your incoming voltage

matches the pump wiring voltage. See PUMP

ELECTRICaL CONNECTIONS.

6

3. Be sure all pipes are filled when priming.

Depending on the length of suction pipes,

several gallons will be needed to fill the entire

system.

3

Advertising