95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.

Well TO pUMp CONNeCTiON (SUCTiON pipe)

4

IL1535

Approx.

12 in.

Well Seal

4. Remove the pipe clamp and slide a well seal

(not included) over the PVC pipe and onto

the well casing. The PVC pipe should extend

approximately 12 in. above the top of the well

seal, depending on the height of the pump.

NOTE: Do not let the assembly slide down into the

well. Tighten the well seal until the rubber gaskets

are tight against the well casing and the PVC pipe.

5

1 in. PVC

Elbow

5. Using a 2-step PVC system, attach a 1 in. PVC

elbow (not included) onto the rigid PVC pipe

extending from the well seal.

7a

1-1/4 in.

opening
1 in.

opening

6. IMPORTaNT: Use short venturi tube in ejector

body for shallow well applications. Do not use

long venturi tube. Ejector must be attached to

front of pump for shallow well applications.

7a. Place gasket against back of ejector so that

openings in gasket line up with openings

in ejector. Line up bolts, 3/8 Lw and flat

washers

with openings in ejector and slide

the bolts through the bolt opening.

6

IL1634

Short

Long