Psb-2800l – GW Instek PSB-2000 Series User Manual User Manual
Page 159

APPENDIX
159
PSB-2800L
Item
Single
Parallel
Series
800L
800L x 2
800L x 3
800L x 4
800L + 800L
800W
1600W
2400W
3200W
1600W
Voltage Setting
SLOW
10mV
FAST
1V
Range
0V-82V
Min. display
digit
10mV
Current Setting
SLOW
10mA
100mA
90mA
80mA
10mA
FAST
1A
10A
9A
8A
1A
Range
0A-82A
0A-164A
0A-246A
0A-328A
0A-82A
Min. display
digit
10mA
100mA
10mA
Power Setting
SLOW
10W
100W
10W
FAST
100W
1000W
100W
Range
10W-820W 20W-1640W 30W-2460W 40W-3280W 10W-820W
Min. display
digit
1W
OVP Setting
SLOW
100mV
FAST
10V
Range
1V-84V
Min. display
digit
10mV
OCP Setting
SLOW
100mA
200mA
300mA
400mA
100mA
FAST
10A
20A
30A
40A
10A
Range
1A-84A
2A-168A
3A-252A
4A-336A
1A-84A
Min. display
digit
10mA
100mA
10mA
For parallel connections, the smallest value that can be displayed (Min. display digit) for
current is 100mA. When some model combinations are used in parallel, the actual current
setting resolution may be different to the display resolution. In this situation the display
may not update with only one click of the encoder.