GW Instek PSB-2000 Series User Manual User Manual
Page 33

OPERATION
33
still if the cables are twisted to reduce noise or to
avoid malfunctioning.
Be careful of the
temperature!
Connecting to the Rear Output Terminals (PSB-2400L,
2800L, 2400L2, 2800LS)
Procedure
1. Remove the AC cable from the AC INPUT.
2. Connect crimped lug terminals to the ends of
the load cables. Tighten the lug terminals
firmly using the nuts supplied with the power
supply.
CAUTION
The rear output terminals have M6 holes and M3
(tapped) holes.
Be sure to use the M6 holes to connect the load.
Noise at the load end may be reduced by twisting
the load cables or connecting a film capacitor
(several μF, low-impedance, high-frequency) and
an electrolytic capacitor (several hundred μF) to
the load end.
Fig. Connection
with Rear Output
Terminals
Bolt (M6)
Washer
Nut
Terminal block
Output terminal bar