GW Instek PSB-2000 Series User Manual User Manual
Page 30

PSB-2000 Series User Manual
30
Pin assignment of J3 external control connector (PSB-2400H,
2800H)
Pin No. Signal name
Function
13
NC
14
EXT CV CONTROL
IN
Constant-voltage control input pin.
In the external voltage control mode, an
external voltage of 0V to 10V can be
used to control the output voltage from
0V to 800V.
In the external resistance control mode,
an external resistance of 0kΩ to 10kΩ
can be used to control the output
voltage from 0V to 800V.
15
EXT CC CONTROL
IN
Constant-current control input pin.
In external voltage control mode, an
external voltage of 0V to 10V can be
used to control the output current from
0A to 3A(400H) or 6A(800H).
In the external resistance control mode,
an external resistance of 0kΩ to 10kΩ
can be used to control the output
current from 0A to 3A(400H) or
6A(800H).
16
COM
COM
Connected with the negative output
terminal.
17
EXT V MON OUT
Output voltage monitor pin.
Outputs approx. 0V to 10V to represent
the output voltage from 0V to 800V.