GW Instek PSB-2000 Series User Manual User Manual
Page 35

OPERATION
35
4. Sandwich the output terminals and the load
cables from above and below with the rear
output terminal protective covers, as shown
below. Drive the screw into the protective
covers at the center.
Fig. Attaching
Rear Output
Terminal
Protective Covers
CAUTION
Make sure that the protection covers are always
attached to the terminals even when they are not
being used.
The front and rear output terminals are
electrically connected internally. Touching a
terminal that is not protected may induce an
electric shock.
The rear output terminals have M6 holes and M3
(tapped) holes. Be sure to use the M6 holes to
connect the load. Noise at the load end may be
reduced by twisting the load cables or connecting
a film capacitor (high-frequency, low-impedance
(several μF) and an electrolytic capacitor (several
hundred μF) to the load end.
5. Cut the shaded parts shown below with cutting
pliers or the like to connect the power supplies
in series or in parallel or to ground the output.