GW Instek PSB-2000 Series User Manual User Manual
Page 63

OPERATION
63
mode.
External Control (External Voltage, External Resistance)
Menu Item: 06(PSB-L), 05(PSB-H)
Introduction
Constant-Voltage (CV) Control Using External
Voltage
This function allows you to control the voltage
of the PSB-2000 series power supply unit by
applying an external voltage to the unit. An
external voltage of 0V to 10V can be used to
control the output voltage from ~0V to the rated
output voltage.
Constant-Current (CC) Control Using External
Voltage
This function allows you to control the current
of the PSB-2000 series power supply unit by
applying external voltage to the unit. An
external voltage of 0V to 10V can be used to
control the output current from ~0A to the rated
output current.
Constant-Voltage (CV) Control Using External
Resistance
This function allows you to control the voltage
of the PSB-2000 series power supply unit by
connecting an external resistance to the unit.
An external resistance of 0Ω to 10kΩ can be
used to control the output voltage from ~0V to
the rated output voltage.
Constant-Current (CC) Control Using External
Resistance
This function allows you to control the current