Caution, 400 series, En - 13 – HT instruments SPEED418 User Manual

Page 14

Advertising
background image

400

Series

EN - 13

1.

Press the MENU key, move the cursor to
AUTO

in the main menu by means of the

arrow keys (,) and confirm with ENTER.
Subsequently the instrument displays a screen
similar to the one reported here to the side.

A U T O

R a = - - - -

T r c d = - - - - m s

R P - P e = - - - - M

30mA

50V 500V

IdN

RCD UL VNom

2.

Use the ,  keys to select the parameter to be modified, and the ,  keys
to modify the parameter value.
It is not necessary to confirm the selection with ENTER

.

IdN

The virtual IdN key allows setting the nominal value of the RCD’s
tripping current, which may be: 10mA, 30mA, 100mA, 300mA,
500mA, 650mA

CAUTION

Make sure to select the correct value when setting the RCD’s test current. If
setting a current higher than the nominal current of the device being tested,
the RCD would be tested at a current higher than the correct one, thus
facilitating a faster tripping of the switch

RCD

The virtual RCD key enables the selection of the RCD type, which
may be: AC, AC S, A, A S (the options A, A S are not available if
the electrical system set is IT)

CAUTION

When activating the test option for selective RDCs (symbol S), the time
interval between the tests is 60 seconds (30 seconds for tests with ½IdN).
The instrument display shows a timer indicating the time remaining before
the instrument can automatically perform the test.

UL

The virtual UL key allows setting the limit value of contact voltage
for the system being tested, which may be: 25V, 50V

VNom

The virtual VNom allows setting the value of test voltage for insulation

measurement, which may be: 50V, 100V, 250V, 500V, 1000V

3. Insert the green, blue and black connectors of the three-pin shuko cable into the

corresponding input leads E, N and P of the instrument. As an alternative, use the
single cables and apply the relevant alligator clips to the free ends of the cables. It is
also possible to use the remote probe by inserting its multipolar connector into the
input lead P. Connect the shuko plug, the alligator clips or the remote probe to the
electrical mains according to Fig. 4 and Fig. 5

4.

Press the GO/STOP key on the instrument or the START key on remote
probe. The instrument will start the automatic test sequence.