Badger Meter Vortex Meters User Manual

Page 18

Advertising
background image

Page 16

haRT interface

There are many HART related fields that can be viewed and set using the “HART Interface” di-

alog box. To bring up this box, click the “Configure Meter” pull-down menu on the Main screen

and then select “HART Interface”.

When this window is opened, the current field values are read from the meter and displayed in

the window.

HART Interface

Tag:
Descriptor:

Message:

Date (d/m/y):
Number of Preambles:
Final Assembly Number:
Universal Command Revision:
Specific Command Revision:
Device ID:

Close

Write

Read

1

2005

7

0

5
1
105

ADVANCED VORTEX TECHNOLOGY

RACINE

5

FL_METER

Message - This field allows the user to enter a message in the HART “Message” field. The

value of this field has no effect on the operation of the meter. The message value can be up to

32 characters of alphanumeric text.

Tag - This field allows the user to enter a descriptive name in the HART “Tag” field. The tag

value can be up to 8 characters of alphanumeric text. The tag value can be used to create a

unique addressing string in multi-drop operation. However, the Racine HART Interface does

not support multi-drop communication so the “Tag” field is solely informational.

Descriptor - This field allows the user to enter text in the HART “Descriptor” field. The value of

this field has no affect on the operation of the meter. The descriptor text can be up to 24 char-

acters of alphanumeric text.

Date - This field allows the user to enter a date in the HART “Date” field. The value of this field

has no affect on the operation of the meter.