Page 22

User Defined Pressure - This field allows the user to enter a constant process pressure.

However, this pressure is only used when “User Defined” is selected as the process pressure

source. The unit for this field is PSIG.

Pressure Reading for 4 mA Analog Input - This field is used to specify the lower range of

the analog pressure input. Enter the pressure value that is associated with 4 mA on the ana-

log pressure input. This information is required when an absolute pressure or gauge pressure

analog input is selected as the process pressure source. The unit for this field is interpreted as

PSIA when an absolute pressure gauge is selected as the process pressure source and PSIG

when a gauge pressure gauge is selected as the process pressure source.

Pressure Reading for 20 mA Analog Input - This field is used to specify the upper range of

the analog pressure input. Enter the pressure value that is associated with 20 mA on the ana-

log pressure input. This information is required when an absolute pressure or gauge pressure

analog input is selected as the process pressure source. The unit for this field is interpreted as

PSIA when an absolute pressure gauge is selected as the process pressure source and PSIG

when a gauge pressure gauge is selected as the process pressure source.

NOTE: Save the changes to EEPROM and put the meter in-service after making changes.

Density and viscosity

The process density and viscosity information can be accessed through the “Density and

Viscosity” dialog box. To bring up this box, click the “Configure Meter” pull-down menu on the

Main screen and then select “Density and Viscosity”.

The data displayed by this window is read from the meter when the window is opened and

when the user clicks the Read or Write buttons.

Density and Viscosity

Standard Density:
Process Viscosity:

Process Density:

Density and Viscosity Source:

lb/CuFt
cP

lb/CuFt

Property Table

Steam Table

Steam Table

User Defined

Property Table Name:
Property Table Version Number:

User Defined Viscosity:

User Defined Density:

cP

lb/CuFt

14.696
0.0185
AIR
2

0.076146

1.816741E-02

Write

Read

Close

7.467528E-02