Switch Modules

Table 1-1 lists the specifications when the switch module is installed in the
mainframe. In the table, the conditions are as follows:

Conditions: 23

°C ± 5 °C, 5 % to 60 % R.H.

Table 1-1

Agilent B2210A/B2211A Switch Module Specifications

Agilent B2200A mainframe supports Agilent B2210A module.

Agilent B2201A mainframe supports Agilent B2211A module.

Mixed configuration of the switch modules is not supported.

B2210A B2211A

Maximum current rating (A)

I-V port

1.0

1.0

AUX port

0.5

0.5

Maximum voltage rating (V)

I-V port, channel to common

200

200

I-V port, channel to other channel

300

300

AUX port, channel to common

100

100

AUX port, channel to other channel

100

100

Closed channel residual resistance (

Ω)

I-V port

0.6

0.6

AUX port

1.5

1.5

Channel isolation resistance (

Ω)

I-V port

10

14

5

× 10

13

AUX port

10

9

10

9