Inverter related options – NORD Drivesystems B1000 User Manual

Page 705

Advertising
background image

www.nord.com

G703

G1000 – Subject to Change Without Notice

MOTORS

Inverter Related

Options

Incremental Encoder (IG..P)

NORD can provide an incremental encoder mounted on
the back of a motor or brake motor. Commonly encoders
are used as speed or position feedback devices for use with
AC drives, motion controllers or PLC’s. Below are standard
encoders; however, others can be supplied on request.

?

Encoder nomenclature must be specifi ed.

Encoder nomenclature

Standard Motor

with Encoder

Encoder with

F Type Blower Fan

Encoder with

Brake Option

Brake Option, Blower Fan

with Encoder

Build

Encoder Type: Quadrature
Differential Marker pulse

IG1 P

IG4 P

IG11 P

IG41 P

IG12 P

IG42 P

IG13 P

IG43 P

Interface

TTL/RS422 (26C31)

TTL/RS422 (26C31)

HTL/Push-pull (IC-WE)

Line Driver (7272)

Logic [VDC]

5

5

10-30

5-30

Pulse Count [PPR]

1024

4096

1024

4096

1024

4096

1024

4096

Power Supply [VDC]

4-6

4-6

10-30

10-30

10-30

10-30

5-30

5-30

Part Number

19551500

19551520

19551502

19551522

19551501

19551521

19551503

19551523

Max Current Draw [mA]

100

150

Max Frequency [kHz]

300

Ambient Temperature [°F]

-4 to185

Enclosure

IP66

Cable

M12 8-pin male plug

Wiring Diagram

Pin

Conn

Cord

1

0V

WH

2

+V

BN

3

A

GN

4

A\

YE

5

B

GY

6

B\

PK

7

Z

BU

8

Z\

RD

Nut

Gnd

Open

2

1

7

6

5

4

3

8

M12 Connector

Interface

Length

In-line

Right-angle

NORD P/N

Turck P/N

NORD P/N

Turck P/N

2m

19551580

E-RKC 8T-264-2

19551584

E-WKC 8T-264-2

5m

19551581

E-RKC 8T-264-5

19551585

E-WKC 8T-264-5

10m

19551582

E-RKC 8T-264-10

19551586

E-WKC 8T-264-10

15m

19551583

E-RKC 8T-264-15

19551587

E-WKC 8T-264-15

Field Wireable

19551588

CMB 818

1-0

-

-

Custom

order from Turck

E-RKC 8T-264-*

order from Turck

E-WKC 8T-264-*

Pre-fabricated Encoder Cables

NORD can provide Turck pre-fabricated encoder molded cordsets (M12, 8-pin, shielded, twisted pair)

• The above encoder cables are provided with the shielding NOT connected thru the plug nut
• Providing a conducting path thru the cable nut and attaching the shield to ground on both ends of cable

is a possible source of electrical noise

Advertising