BRAKES

Current Sensing Relay (IR)

The current sensing relay, is used to achieve a fast
brake engagement (stopping) without the use of
external control equipment or additional wiring. The
relay is mounted directly on the conduit box, and
is powered from the motor’s terminal block. The
power leads for the relay replace one of the brass
jumper bars on the terminal block of any single
speed motor. The switch leads are connected to
terminals 3 and 4 of the rectifi er. When the power
to the motor is shut off, the IR relay opens the brake
circuit on the DC side which allows the brake to
de-magnetize quickly.

Mod

Requirements

• Brake must be powered from the motor’s terminal
block (not seperately powered)


• Motor must be a single speed and should not be
powered by a frequency inverter or soft starter.

CAUTIONS

Ratings

Part number

18556010

18556020

Motor Frame Sizes

*63S - 180M

180L - 225M

AC Input Current
- black/white wires

25A

AC

75A

AC

- 0.2 s

50 A

AC

75 A

AC

- 0.2 s

DC Brake Current
- red/blue wires

2.0 A

DC

2.0 A

DC

Additional Brake
Setting Delay

18 ms

18 ms

Ambient Temperature

- 40 to 75 °C

- 40 to 167 °F

- 40 to 75 °C

- 40 to 167 °F

Enclosure Rating

IP65

IP65

* For 180MX motor frame at 230/460V use part number
18556020

Connection Notes

Rectifi er

IR-Relay Wires

to Rectifi er

Model
Type

Part

Number

Design

Red

Blue

GVE20L

1914000

Full-wave

3

4

GHE40L

19141010

Half-wave

4

3

GHE50L

19141020

Half-wave

4

3

GPE20L

19140230

Push-hybrid

4

3

GPE40L

19140240

Push-hybrid

4

3

Conduit Box Thread Adapter

Thread

Motor Frame

Part Number

M20

63-71

18542006*

M25

80-90

18522253

M32

100-132

18522320

M40

160-180

18522400 + 18522253

* Spacer