G705

G1000 – Subject to Change Without Notice

MOTORS

Inverter

SK 300E Trio

Basic NORD

Power

240 VAC Input Inverter

480 VAC Input Inverter

Motor

Rating

P

Type

Type

Description

HP/kW

[in]

SK 300E

SK 300E

63 S/4

0.16 / 0.12

5.12

-370-323-B

-550-340-B

63 L/4

0.25 / 0.18

5.12

-370-323-B

-550-340-B

71 S/4

0.33 / 0.25

5.71

-370-323-B

-550-340-B

71/L/4

0.50 / 0.37

5.71

-370-323-B

-550-340-B

80 S/4

0.75 / 0.55

6.5

-550-323-B

-550-340-B

80 L/4

1.00/ 0.75

6.5

-750-323-B

-750-340-B

90 S/4

1.50/ 1.1

7.2

-111-323-B

-111-340-B

90 L/4

2.00/ 1.5

7.2

-151-323-B

-151-340-B

100 L/4

3.00/ 2.2

7.91

-221-323-B

-221-340-B

100 LA/4

5.00/ 3.7

7.91

Not Available

-401-340-B

Type designation SK 300E

Type designation SK 300E

-370-323-B

-370-323-B -550-323-B

-550-323-B -750-323-B

-750-323-B -111-323B

-111-323B -151-323-B

-151-323-B -221-323-B

-221-323-B -550-340-B

-550-340-B -750-340-B

-750-340-B -111-340-B

-111-340-B -151-340-B

-151-340-B -221-340-B

-221-340-B -301-340-B

-301-340-B -401-340-B

-401-340-B

Supply Voltage

Supply Voltage

3 Phase 200-240 VAC +/- 10%, 47-63 Hz

3 Phase 380-480 VAC, -20%/+10%, 47-63 Hz

Motor Rating

Motor Rating

1/2 HP

3/4

1 HP

1 1/2 HP

2 HP

3 HP

3/4 HP

1 HP

1 1/2 HP

2 HP

3 HP

4 HP

5 HP

Rated Output Current Amps [RMS]

Rated Output Current Amps [RMS]

2.2

3

4

5.5

7

9.5

1.6

2.2

3

3.7

5.5

7

9.2

Typical Output Current Amps [RMS]

Typical Output Current Amps [RMS]

3.1

4.2

5.6

7.7

9.8

13.3

2.5

3.1

4.2

5.2

7.7

9.8

12.9

Inverter Ratings

NORDAC SK 300E
Motor Mounted Frequency Inverter

For select HP ratings, NORD can provide a fully programmable,
high performance AC vector frequency inverter mounted on the
motor. This motor mounted inverter:

• Eliminates the need to separately mount & wire the inverter
• Insures inverter/motor compatibility
• Has an IP 55 washdown duty enclosure
• Provides Electronic Motor Overload protection
• Insures smooth constant torque operation down to

2 Hz (check motor thermal limitations)

• Features a unique plug-in construction where the

program stays with the motor, minimizing return to

service time in the event of inverter replacement

SK 300E Inverter Ratings

• 200-240 VAC 3 phase 50/60 Hz input, ½ through 3 HP
• 380-480 VAC 3 phase 50/60 Hz input, 3/4 through 5 HP
• Full range of built-in pre-engineered options available

Selection Steps

1) Choose the SK300E-trio inverter based on motor ratings and input line voltage

2) Select the required Trio Interface (TI)

3) Select the braking resistor if required

4) Select additional customer based I/O if required (SK CU2-STD)

5) Select cover mounted technology unit if required

6) If remote wall mounting is required

7) Select any needed programming tools

Step 1: Inverter Selection