Performance data – NORD Drivesystems B1000 User Manual

Page 714

Advertising
background image

www.nord.com

G712

G1000 – Subject to Change Without Notice

MOTORS

Performance Data

Standard Effi ciency

Inverter duty • TEFC
Synchronous speed 1800rpm @ 60Hz • 4-pole • Three-phase
Voltages: 230/460V – 60Hz • 1.15 Service Factor
Continuous Duty • 40°C Ambient • up to 3300ft Elevation
Class B temperature rise • Class F insulation

230/460V – 60Hz

Motor

Type

Power

Pn

Nn

Full-
load

In

Full-Load Cur-

rent

Ia/In

Code

Letter

Torque

Tn

Ta/Tn

Tk/Tn

pf

Eff.

Jm

Inertia

230V

a)

460V

a)

[hp]

[kW]

[rpm]

[A]

[A]

[%]

[lb-in]

[%]

[lb-ft

2

63S/4

0.16

0.12

1700

0.88

0.44

245

F

5.92

2.1

2.2

0.66

52

0.005

63L/4

0.25

0.18

1680

1.12

0.56

275

E

8.99

2.1

2.2

0.71

57

0.0067

71S/4

0.33

0.25

1710

1.56

0.78

310

G

12.3

2.5

2.4

0.64

63

0.017

71L/4

0.5

0.37

1720

1.90

0.95

355

F

18.0

2.45

2.6

0.69

71

0.0204

80S/4

0.75

0.55

1710

2.70

1.35

355

F

27.0

2.2

2.2

0.71

72

0.0259

80L/4

1

0.75

1650

3.66

1.83

390

G

38.1

2.2

2.3

0.74

70

0.0345

90S/4

1.5

1.1

1660

4.84

2.42

445

G

55.6

2.7

2.6

0.78

73

0.055

90L/4

2

1.5

1660

6.34

3.17

465

G

75.8

2.55

2.5

0.80

74

0.074

100L/4

3

2.2

1705

9.0

4.50

490

G

108

2.3

2.6

0.81

82

0.107

100LA/4

5

3.7

1725

15.2

7.62

510

G

180

2.7

3.1

0.75

81

0.141

132S/4

7.5

5.5

1735

19.8

9.9

545

G

267

2.45

2.75

0.82

86

0.55

132M/4

10

7.5

1735

25.8

12.9

645

H

363

2.9

3.2

0.84

87

0.752

160M/4

15

11

1770

38.4

19.2

665

H

522

2.45

3.0

0.82

88

0.95

160L/4

20

15

1765

49

24.5

725

H

713

2.9

3.3

0.86

89.4

1.23

180MX/4

25

18.5

1750

60

30

860

K

887

2.95

3.4

0.87

89

1.35

180LX/4

30

22

1755

71

35.5

980

L

1052

3.4

3.7

0.87

89.4

1.35

200L/4

40

30

1780

96

48

770

J

1414

2.9

3.6

0.85

92

5.70

225S/4

50

37

1765

-

58

760

H

1759

3.1

3.5

0.86

93.1

7.60

225M/4

60

45

1770

-

70

840

J

2133

3.1

3.6

0.86

93.8

8.54

250M/4

75

55

1782

-

89

700

H

2636

2.8

3.2

0.84

93.7

16.4

280S/4

100

75

1788

-

118

830

J

3497

2.9

3.5

0.84

94.4

30.6

280M/4

125

90

1786

-

144

810

J

4385

2.8

3.3

0.86

95.1

34.9

315S/4

150

110

1788

-

176

720

H

5255

2.8

3.1

0.84

94.7

47.5

315M/4

175

132

1790

-

200

800

J

6125

3.0

3.4

0.85

95.4

58.4

315Ma/4

200

150

1790

-

230

810

J

7003

3.2

3.6

0.86

95.7

71.4

315L/4

250

187

1790

-

280

850

J

8734

3.2

3.3

0.87

96.3

92.8

a) Motors frame 225 and larger are standardly provided as single-voltage 460V and not as dual voltage

Pn

-

Full load power

Nn

-

Full load speed

In

-

Full load current

Ia - Locked-rotor

current

Ia/In

-

Locked-rotor current ratio (%)

Tn - Full-load

torque

Ta - Locked-rotor

torque

Ta/Tn

-

Locked-rotor torque ratio

Tk - Break-down

torque

Tk/Tn

-

Break-down torque ratio

pf - Power

factor

Eff -

Normal

effi ciency

Jm - Motor

inertia

Advertising