Performance data – NORD Drivesystems B1000 User Manual

Page 718

Advertising
background image

www.nord.com

G716

G1000 – Subject to Change Without Notice

MOTORS

Performance Data

Standard Effi ciency

Inverter duty • Induction motor • TEFC
Synchronous speed 1800rpm @ 60Hz • 4-pole • Three-phase
Voltages: 208V – 60Hz • 1.15 Service Factor
Continuous Duty • 40°C Ambient • up to 3300ft Elevation
Class B temperature rise • Class F insulation

200-208V – 60Hz

Motor

Type

Power

Pn

Nn

Full-load

In

208V

Ia/In

Code

Letter

Torque

Tn

Ta/Tn

Tk/Tn

pf

Eff.

Jm

Inertia

[hp]

[kW]

[rpm]

[A]

[%]

[lb-in]

[%]

[lb-ft

2

63S/4

0.16

0.12

1700

0.97

245

F

5.93

2.1

2.2

0.66

52

0.005

63L/4

0.25

0.18

1680

1.24

275

E

9.38

2.1

2.2

0.71

57

0.0067

71S/4

0.33

0.25

1710

1.73

310

G

12.2

2.5

2.4

0.64

63

0.015

71L/4

0.5

0.37

1720

2.10

355

F

18.3

2.45

2.6

0.69

71

0.0181

80S/4

0.75

0.55

1710

2.99

355

F

27.6

2.2

2.2

0.71

72

0.0304

80L/4

1

0.75

1650

4.05

390

G

38.2

2.2

2.3

0.74

70

0.0392

90S/4

1.5

1.1

1660

5.35

445

G

57.0

2.7

2.6

0.78

73

0.0670

90L/4

2

1.5

1660

7.01

465

G

75.9

2.55

2.5

0.80

74

0.0855

100L/4

3

2.2

1705

9.95

490

G

111

2.3

2.6

0.81

82

0.107

100LA/4

5

3.7

1725

16.8

510

G

183

2.7

3.1

0.75

81

0.162

132S/4

7.5

5.5

1735

21.9

545

G

272

2.45

2.75

0.82

86

0.553

132M/4

10

7.5

1735

28.5

645

H

363

2.9

3.2

0.84

87

0.753

Pn

-

Full load power

Nn

-

Full load speed

In

-

Full load current

Ia - Locked-rotor

current

Ia/In

-

Locked-rotor current ratio (%)

Tn - Full-load

torque

Ta - Locked-rotor

torque

Ta/Tn

-

Locked-rotor torque ratio

Tk - Break-down

torque

Tk/Tn

-

Break-down torque ratio

pf - Power

factor

Eff -

Normal

effi ciency

Jm - Motor

inertia

Advertising