3 Displays and diagnosis

BU 0290 GB-4312

Subject to technical amendments

23

3.2 RJ12 Diagnostic socket

All participants which are coupled via a common system bus (field bus module / frequency inverter (up to 4
devices)) can be read out and edited/parameterised via an RJ12 diagnostic socket. This can be either the
diagnostic socket of the frequency inverter or that of the BUS connection units. This provides users with a
convenient facility to perform diagnosis and parameterisation from a central point, without having to access the
particular frequency inverter at its location.

Terminal/
Designation

Function

Data

Description /
wiring suggestion

Parameter


Diagnostic access / RJ12, RS485/RS232

1

RS485 A

Data cable RS485

Baud rate
9600…38400Baud
Termination
resistor
 R=120 


to be set by customer at
the final participant.

V

RE

F

1

0

V

A

G

N

D

0

V

A

IN

1

+

A

IN

2

+

A

O

U

T

1

D

IG

I

N

1

D

IG

I

N

2

D

IG

I

N

3

D

IG

I

N

4

V

O

+

1

5

V

D

G

N

D

0

V

11

12

13

14

16

22

23

24

25

42

40

21

D

IG

I

N

5

1

2

3

4

RE

L

2

.2

RE

L

2

.1

RE

L

1

.2

RE

L

1

.1

C

A

N

_

H

C

A

N

_

L

C

A

N

_

G

N

D

nc

C

A

N

_

S

H

L

D

C

A

N

_

G

N

D

nc

C

A

N

_

2

4

V

C

A

N

_

H

C

A

N

_

L

C

A

N

_

G

N

D

nc

C

A

N

_

S

H

L

D

C

A

N

_

G

N

D

nc

C

A

N

_

2

4

V

R

S

4

8

5

_

A

R

S

4

8

5

_

B

G

N

D

T

X

D

R

X

D

41

V

O

+

5

V

+

5

V

+

2

4

V

RJ12: Pin No. 1 … 6

1: RS485_A
2: RS485_B
3: GND
4: RS232_TxD
5: RS232_RxD
6: +24V

P502
...P513

2

RS485 B

3

GND

Reference potential
for BUS signals

0V digital

4

232 TXD

Data cable RS232

Baud rate
9600…38400Baud

5

232 RXD

6

+24V

24V voltage supply
from FI

24V

20%

Table 9 RJ12 socket connections


The bus speed of the diagnostic interface is 38400 baud. Communication is carried out according to the USS
protocol.

NOTE

Simultaneous use of several diagnostic sockets with several diagnostic tools may lead to
errors during communication. Therefore, only one diagnostic socket within a system bus
network should be used.


The ParameterBox SK PAR-3H is available as a diagnostic tool.