2 delivery, 3 scope of supply, 4 certifications – NORD Drivesystems BU0290 User Manual

Page 7: 1 european emc directive, 2 rohs compliance, 4 certifications 1.4.1

Advertising
background image

1 General

BU 0290 GB-4312

Subject to technical amendments

7

1.2 Delivery

Check the equipment immediately after delivery/unpacking for transport damage such as deformation or
loose parts.
If there is any damage, contact the carrier immediately and carry out a thorough assessment.

Important! This also applies even if the packaging is undamaged.

1.3 Scope of supply

Standard version:

SK TU4-PNT(-C)

IP55 (optionally IP66)

Operating instructions as PDF file on CD ROM
including NORD CON, (Windows PC-based parameterisation software)



Available accessories: SK TI4-TU-BUS(-C) (bus connection unit, required for SK

TU4…)

SK TIE4-WMK-TU, wall-mounting kit TU4

M12 round plug connector (Section 8.2 "Cable glands and shielding connections")

Matching RJ12 to SUB-D9 adapter cable to connection to a PC

ParameterBox: SK PAR-3H, plain text LCD display


1.4 Certifications

1.4.1

European EMC Directive

If the NORD frequency inverter or its options are installed according to the
recommendations in this instruction manual, it meets all EMC directive
requirements, as per the EMC product standard for motor-operated systems
EN 61800-3. (see also Section 8.1.3 , "Cable layout and shielding (EMC
measures)")


1.4.2

RoHS compliance

The bus options described here are designed to be RoHS compliant
according to Directive 2002/95/EEC

Advertising