1.6 Version with protection class IP55 / IP66

NORD SK 200E frequency inverters and the external additional modules are available in all sizes and
powers in the protection classes IP55 (standard) or IP66 (optional).
The protection class IP66 must always be stated when ordering!
There are no restrictions or differences to the scope of functions in either protection class. In order to
differ

entiate the protection classes, modules with protection class IP66 are given an extra “-C” (coated

coated PCBs) in their type designation.

e.g. SK TU4-PNT-C

IP55 version:
The IP55 version of the external technology units is the standard version. Both versions (inverter-mounted
– as a supplement to the frequency inverter or wall mounted on the wall bracket) are available.

IP66 version:
In contrast to the IP55 version the IP66 version is a modified option. With this design, both versions
(inverter-mounted or wall-mounted) are also available. The modules available for the IP66 version (adapter
units, technology units and customer units) have the same functionalities as the corresponding modules for
the IP55 version.

NOTE

The modules for the IP66 design are identified by an additional "-C" and are modified
according to the following special measures!


Special measures:

Impregnated PCBs, coated housing
Diaphragm valve for pressure compensation on temperature changes.
Low pressure test

 A free M12 screw connection is required for low pressure testing. After successful testing, a

diaphragm valve is inserted here. This screw connections is therefore no longer available
for a cable gland.

NOTE

For all versions, care must be taken that the cable and the cable gland are carefully
matched. This is essential to ensure that the required protection class is maintained.