Specifications, Server specifications, Environmental specifications – HP ProLiant ML370 G5 Server User Manual

Page 119

Advertising
background image

Specifications 119

Specifications

Server specifications

Specification Value

Dimensions

Rack model

Height

21.92 cm (8.63 in)

Depth

65.41 cm (26.5 in)

Width

44.45 cm (17.50 in)

Tower model

Height

47 cm (18.5 in)

Depth

71.1 cm (28 in)

Width

21.92 cm (8.63 in)

Weight

Weight (maximum)

40.8 kg (110 lb)

Weight (when lightly loaded) 24.9 kg (55 lb)

Input requirements

Rated input voltage

100 VAC to 240 VAC *

Rated input frequency

47 Hz to 63 Hz

Rated input current

10 A (100 V) to 6.7 A (200 V)

Rated input power

1500 W

BTUs per hour

2730

Power supply output

Rated steady-state power

800 W (low line), 1000 W (high line)

Maximum peak power

1000 W (low line), 1200 W (high line)

* 100 to 127 VAC is required for 10 A; 200 to 240 VAC is required for 6.7 A.

Environmental specifications

Specification Value

Temperature range*

Operating 10

°

C to 35

°

C (50

°

F to 95

°

F)

Shipping -40

°

C to 70

°

C (-40

°

F to 158

°

F)

Maximum wet bulb temperature 28

°

C (82.4

°

F)

Advertising