Specifications, Server specifications, Environmental specifications – HP ProLiant ML370 G5 Server User Manual
Page 119
Specifications 119
Specifications
Server specifications
Specification Value
Dimensions
Rack model
—
Height
21.92 cm (8.63 in)
Depth
65.41 cm (26.5 in)
Width
44.45 cm (17.50 in)
Tower model
—
Height
47 cm (18.5 in)
Depth
71.1 cm (28 in)
Width
21.92 cm (8.63 in)
Weight
Weight (maximum)
40.8 kg (110 lb)
Weight (when lightly loaded) 24.9 kg (55 lb)
Input requirements
Rated input voltage
100 VAC to 240 VAC *
Rated input frequency
47 Hz to 63 Hz
Rated input current
10 A (100 V) to 6.7 A (200 V)
Rated input power
1500 W
BTUs per hour
2730
Power supply output
Rated steady-state power
800 W (low line), 1000 W (high line)
Maximum peak power
1000 W (low line), 1200 W (high line)
* 100 to 127 VAC is required for 10 A; 200 to 240 VAC is required for 6.7 A.
Environmental specifications
Specification Value
Temperature range*
Operating 10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping -40
°
C to 70
°
C (-40
°
F to 158
°
F)
Maximum wet bulb temperature 28
°
C (82.4
°
F)