Configuration and utilities 85

NOTE:

The server may not support all the following examples.

NOTE:

If the boot drive is not empty or has been written to in the past, ORCA does not

automatically configure the array. You must run ORCA to configure the array settings.

Drives Installed

Drives Used

RAID Level

1 1 RAID

0

2 2 RAID

1

3, 4, 5, or 6

3, 4, 5, or 6

RAID 5

More than 6

0

None

To change any ORCA default settings and override the auto-configuration process, press the F8 key when

prompted.
By default, the auto-configuration process configures the system for the English language. To change any

default settings in the auto-configuration process, such as the settings for language, operating system, and
primary boot controller, execute RBSU by pressing the F9 key when prompted. After the settings are

selected, exit RBSU and allow the server to reboot automatically.
For more information, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD or

the HP website (

http://www.hp.com/support/smartstart/documentation

).

HP ProLiant Essentials Rapid Deployment Pack

The RDP software is the preferred method for rapid, high-volume server deployments. The RDP software

integrates two powerful products: Altiris Deployment Solution and the HP ProLiant Integration Module.
The intuitive graphical user interface of the Altiris Deployment Solution console provides simplified point-

and-click and drag-and-drop operations that enable you to deploy target servers, including server blades,

remotely. It enables you to perform imaging or scripting functions and maintain software images.
For more information about the RDP, refer to the HP ProLiant Essentials Rapid Deployment Pack CD or
refer to the HP website (

http://www.hp.com/servers/rdp

).

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.

1.

During the server startup sequence, press the F9 key to access RBSU.

2.

Select the System Options menu.

3.

Select Serial Number. The following warning is displayed:

WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.

4.

Press the Enter key to clear the warning.

5.

Enter the serial number and press the Enter key.

6.

Select Product ID.

7.

Enter the product ID and press the Enter key.