Hardware options installation 48

8.

Install the memory board.

9.

Install the processor air baffle.

10.

Install the access panel (on page

26

).

11.

Do one of the following:

o

Close or install the tower bezel, as needed.

o

Slide the server back into the rack.

12.

Power up the server.

13.

Configure the memory.

FBDIMM installation guidelines

Always observe the following guidelines when installing additional memory:

Always install memory in pairs of equal capacity.

Install FBDIMMs into both slots within a single bank.

Always install memory in pairs in sequential bank order, starting with bank A.

Install supported DDR2 FBDIMMs.

For maximum performance, install a minimum of four FBDIMMs across both memory boards (two

FBDIMMs per board).

For online spare and mirrored memory support, always observe additional guidelines ("

Online spare

memory

" on page

44

).

Removing FBDIMMs

To remove the component:

1.

Power down the server (on page

20

).

2.

Do one of the following:

o

Open or remove the tower bezel, as needed ("

Open or remove the tower bezel

" on page

21

).

o

Extend the server from the rack (on page

22

).