Table 31 – HP StorageWorks XP Remote Web Console Software User Manual

Page 202

Advertising
background image

Table 31 General Troubleshooting Information for Universal Replicator for Mainframe

Error

Corrective Action

The HP XP Remote Console software hangs,

or URz operations do not function properly.

Make sure that all URz requirements and restrictions are met

(e.g., track format, VOLSER).
Make sure the primary and secondary storage systems are

powered on and fully for operational and operational (NVS,

cache, DFW). Refer to the XP disk array owner’s guide

troubleshooting information.
Check all the entered values and parameters to make sure you

entered the correct information on the Universal Replicator for

Mainframe windows (e.g., remote storage system S/N, path

parameters, primary data volume IDs and secondary data

volume IDs).

Status of pairs and/or logical paths is not

displayed correctly.

Make sure that the correct CU image is selected.

An R-SIM warning is displayed on your HP

XP Remote Web Console computer.

Locate the SIM (see the XP Remote Web Console user’s guide

for instructions). For information about UR-z/OS SIMs, see

Universal Replicator for Mainframe Software Error Codes

.

A URz error message is displayed on your

XP Remote Web Console computer.

Remove the error cause, and then retry the URz operation.

There is a problem with the XP Remote Web

Console computer or the URz software.

Make sure that the problem is not with the computer, LAN

hardware or software. Restart the computer and retry

connecting to the storage system.

The status of a logical path is not normal.

Check the path status in the DKC Status window, and see

Table 31

.

The pair status is suspended.

Check the detailed pair status in the Detailed Information

window. See

Table 33

on page 204 for suspend types and

corrective action for suspended URz pairs.

Table 32 Troubleshooting Problems with Status of Logical Paths

Path Status

Description

Corrective Action

Initialization

Failed

The link initialization

procedure for the remote

storage system failed.

Make sure that the local and remote storage systems are

correctly connected via cable to each other.
Make sure that you entered the correct remote storage

system S/N (serial number) and path parameters (e.g.,

local storage system port, remote storage system port, and

controller ID).
Make sure that the topology settings of the local and

remote storage system ports are correct.

Communication

Time Out

Communication between the

local and remote storage

systems timed out.

Make sure that the remote storage system is powered on,

and that NVS and cache are fully functional.
Make sure that network relay devices (including cables,

connectors, ESCDs, extender devices, communication

lines, and all other devices connected to the extenders)

are properly configured and functional. After that, delete

the failed path. You may need to change the minimum

paths setting or delete the remote storage system in order

to delete the path. After deletion finishes, add the path or

the remote storage system by using the Add Path window

or the Add DKC window.

202 Troubleshooting

Advertising
This manual is related to the following products: