In delta resync operation, the status of the URz pair will not change to Pending Duplex but Duplex. This is

because delta resync operation copies only the really necessary data by journal copying. Compared to

the usual way which copies the whole data in the primary data volume, delta resync operation requires

shorter time for the recovery of the URz pair after a failure occurs.

NOTE:

When the total capacity of stored journal data exceeds 80% of the journal volume of TCz Synchronous

secondary site, old journal data will be deleted automatically. Therefore, if the total capacity of the journal

data which is not restored to the URz secondary data volume exceeds 80% of the journal volume, the

secondary data volume will not be able to be restored completely by copying the journal data to the restore

journal volume in the URz secondary site. In that case, according to the setting of the journal group

option, whole data in the primary data volume will be copied to the secondary data volume, or delta

resync operation finishes without any processing.

Usually, if the pair between TCz Synchronous primary site and secondary site is synchronized periodically,

the total capacity of the journal data which is not restored to the URz secondary site will not exceed

80% of the journal volume. Though, for example if the URz pair is suspended and the pair has not been

resynchronized for a long time, journal data of more than 80% of the journal volume capacity may be

stored before they are restored to URz secondary data volume. In such case, you may not perform

delta resync operation properly.

WARNING!

Even if the capacity of the journal data does not exceed 80% of the journal volume, the journal data will or

may be destroyed in the following cases.

When you restore the TCz Synchronous pair, then updated the M-VOL

When you restore the URz pair between the primary site and the URz secondary site, then

updated the M-VOL

When the retry processing occurs because of a delay of the M-VOL update

When the update of the TCz Synchronous R-VOL is delayed

As shown in

Figure 8

on page 44, after delta resync operation is performed properly and the primary

site A is recovered from the failure, then the URz pair between the primary site A and the URz

secondary site will be the pair for delta resync operation and become prepared for the failure in the

primary site B. For information about the requirements to perform delta resync operation properly, see

Requirements for Performing Delta Resync Operation

” on page 96.

URz Pair Status

URz displays the pair status for each data volume of specified CU Image (CUI) in the connected XP

storage system.

Table 4

on page 47 lists and describes the URz data volume pair status descriptions.

The primary storage system maintains the status of the primary data volume and can change the pair

status of the primary data volume and secondary data volume. The secondary storage system maintains

the status of the secondary data volume and can change the pair status of the secondary data volume

but not the primary data volume. The primary storage system will detect when the secondary storage

system changes the secondary data volume status (if the path status is normal) and will change the

primary data volume status accordingly. You can display the detailed pair status information at the XP

Remote Web Console remote console PC (URz Pairdisplay window) or at the host processor (Business

Continuity Manager Pairdisplay command).
A volume which is not assigned to a URz data volume pair has the status simplex. When a URz data

volume pair is started, the primary storage system changes the status of the primary data volume and

secondary data volume to pending duplex. When the initial copy operation is complete, the primary

storage system changes the status of both data volumes to duplex. When a pair is suspended from the

primary storage system, the primary storage system changes the status of the primary data volume and

Hitachi Universal Replicator for z/OS user guide for XP12000/XP10000 Disk Arrays and SVS 200

45