34 resolving urz pair suspension, Table 34 – HP StorageWorks XP Remote Web Console Software User Manual

Page 206

Advertising
background image

Table 34 Resolving URz Pair Suspension

Classifica­

tion

Causes of Suspension

SIM

Recovery procedure

Primary

storage

system

hardware or

secondary

storage

system

hardware

Hardware redundancy has been lost

due to some blockade condition. As

a result, one of the following could not

complete: primary-secondary storage system

communication, journal creation, copy

operation, restore operation, staging process,

or de-staging process.
Journals cannot be retained because some

portion of the cache memory or the shared

memory has been blocked due to hardware

failure.
The primary storage system failed to create

and transfer journals due to unrecoverable

hardware failure.
The secondary storage system failed to receive

and restore journals due to unrecoverable

hardware failure.
The drive parity group was in correction-access

status while the URz pair was in Pending

Duplex status.

DC0x

DC1x

DC2x

According to SIM, remove the

hardware blockade or failure.
Restore the failed volume pairs

(Resume Pair).
If a failure occurs when Business

Continuity Manager is being used,

secondary volumes in Suspend

(equivalent to SWAPPING in

Business Continuity Manager)

may remain in the master journal

group. If these volumes remain,

execute the YKRESYNC REVERSE

option on the secondary volumes

whose pair status is Suspend,

which is equivalent to SWAPPING

in Business Continuity Manager

terminology (YKRESYNC is the

Business Continuity Manager

command for resynchronizing

pair). This operation changes

all volumes in the master journal

group to primary volumes. After

this operation, restore the volume

pairs (Resume Pair).

Communi­

cation be­

tween the pri­

mary and sec­

ondary stor­

age systems

Communication between the storage systems

failed because the secondary storage system

or network relay devices were not running.
Journal volumes remained full even after the

timeout period elapsed.

DC0x
DC1x

Remove the failure from the primary

and secondary storage systems or

the network relay devices.
If necessary, increase resources as

needed (e.g., the amount of cache,

the number of paths between

primary and secondary storage

systems, the parity groups for

journal volumes, etc.).
Restore the failed pairs (Resume

Pair).

RIO overload

or RIO failure

An unrecoverable RIO (remote I/O) timeout

occurred because the storage system or

networks relay devices were overloaded. Or,

RIO could not be finished due to a failure in

the storage system.

DC2x Release failed pairs (Delete Pair).

If necessary, increase resources as

needed (e.g., the amount of cache,

the number of paths between

primary and secondary storage

systems, the parity groups for

journal volumes, etc.).
Re-establish failed pairs (Add Pair).

Planned

power outage

to the primary

storage

system

The URz pairs were temporarily suspended

due to a planned power outage to the primary

storage system.

DC8x No recovery procedure is required.

The primary storage system

will automatically remove the

suspension condition when the

storage system is powered on.

Universal Replicator for Mainframe Software Error Codes

XP Remote Web Console computers display an error message when an error occurs during URz

operations. The error message describes the error and displays an error code consisting of four digits.

The error message may also include an XP SVP error code. If you need to call the HP Support Center

206 Troubleshooting

Advertising