Path Status

Description

Corrective Action

Resource

Shortage (Port)
or,
Resource

Shortage

(Pair-Port)

The local and remote storage

system rejected the request

for creating a logical path

because all resources in the

local and remote storage

systems are being used for

other connections.

Delete the failed path, and also delete all paths and

remote storage systems not currently in use. The local

storage system can be connected to up to 64 remote

storage systems with up to eight paths to each remote

storage system.
Make sure all local and remote storage system ports

are properly configured: ordinary target ports or RCU

target ports for hosts, RCU target ports for remote storage

systems, initiator ports for local storage systems.
If necessary, connect to the remote storage system to delete

paths or remote storage systems and reconfigure ports,

then reconnect to the local storage system. After that, add

the path or the remote storage system again by using the

Add Path window or the Add DKC window.

Serial Number

Mismatch

The serial number (S/N) of

the remote storage system

does not match the specified

serial number (S/N).

Make sure that you entered the correct remote storage

system S/N and path parameters (e.g., local storage

system port, remote storage system port, and controller ID).

After that, delete the failed path. You may need to change

the minimum paths setting or delete the remote storage

system in order to delete the path. After deletion finishes,

add the path and the remote storage system again by

using the Add Path window or the Add DKC window.
Make sure that you entered the correct controller ID, and

also make sure that the topology settings of the local and

remote storage system ports are correct.

Invalid Port

The specified port is not

configured as an RCP or

initiator port, or this path

already exists.

Make sure that the topology settings of the local and

remote storage system ports are correct.
Make sure that you entered the correct remote storage

system S/N and path parameters (e.g., local storage

system port, remote storage system port, and controller ID).

After that, delete the failed path. You may need to change

the minimum paths setting or delete the remote storage

system in order to delete the path. After deletion finishes,

add the path and the remote storage system again by

using the Add Path window and the Add DKC window.

<blank>

This path was not

established.

Delete the failed path. You may need to change the

minimum paths setting or delete the remote storage system

in order to delete the path. After deletion finishes, add the

path and the remote storage system again by using the

Add Path window and the Add DKC window.

Pair-Port Number

Mismatch

The specified port in the

remote storage system is

physically disconnected from

the local storage system.

Make sure that you specified the correct remote storage

system port. Correct the port number if necessary.
Make sure that the local storage system port and the

remote storage system port are connected via cables to

each other. If the storage systems are not connected via

cables, please connect them via cables and then retry the

operation.
Make sure that the topology settings of ports on the local

and remote storage systems are correct.

Pair-Port Type

Mismatch

The specified port in the

remote storage system is not

configured as an RCU Target

port.

Make sure that the specified port in the remote storage

system is configured as an RCU target port. Configure the

port as an RCU target port if it is not configured that way.

Communication

Failed.

The local storage system

is connected to the remote

storage system successfully,

but logical communication

timeout occurred.

Make sure that the remote storage system port and network

relay devices (e.g., cables and switches) are properly

configured and functioning.

Hitachi Universal Replicator for z/OS user guide for XP12000/XP10000 Disk Arrays and SVS 200

203