Urz suspension condition, 7 urz suspension condition, Suspension condition – HP StorageWorks XP Remote Web Console Software User Manual

Page 50

Advertising
background image

Table 6 Consistency Status for Suspended URz Secondary Data Volumes

Consistency

Status

Description

Volume

This URz volume pair was suspended alone. Update sequence consistency between

this secondary data volume and other secondary data volumes in this journal group is

not ensured. This secondary data volume cannot be used for disaster recovery at the

secondary system. This status is indicated when:

This volume pair was suspended by a user-initiated suspend pair operation with

the URz Suspend option set to Volume.

This volume pair was suspended due to a failure that did not affect the entire

consistency group, and the Error Level pair option for this pair is set to Volume.

Group

This URz volume pair was suspended along with the other pair in its journal group.

Update sequence consistency between this secondary data volume and other secondary

data volumes in this journal group is ensured. This secondary data volume can be used

for disaster recovery at the secondary system (after releasing the URz volume pair from

the secondary storage system). This status is indicated when:

This volume pair was suspended by a user-initiated suspend pair operation with

the URz Suspend option set to Group.

All volume pairs in this journal group were suspended due to a failure that affected

the entire journal group (not just one pair) (e.g., primary storage system-secondary

storage system communication failure).

The volume pair was suspended due to a failure that did not affect the entire group.

URz Suspension Condition

URz operations also involve suspension conditions related to asynchronous operations. Both the primary

storage system and secondary storage system can detect URz suspension conditions and suspend URz

pairs.
The URz suspension conditions described in

Table 7

on page 50 and indicates which CU detects

the condition and which pairs are suspended. See

General Troubleshooting

” on page 201 for

troubleshooting information for URz suspension conditions.

Table 7 URz Suspension Condition

Suspension Condition

Detected by:

URz Pairs to be Suspended

The secondary storage system could not copy the

journal data successfully due to a hardware failure

or logic error.

RCU

All URz secondary data volumes in

the journal groups, or the affected

secondary data volume.

The secondary storage system detected a logical

error while selecting the journal data to be restored.

RCU

All the URz secondary data volumes

in the journal group, or only the

affected secondary data volume,

depending on the type of failure.

The secondary storage system could not restore

the journal data due to a hardware failure, track

condition, or logical error.

RCU

The primary storage system stores the differential bitmap per URz primary data volume in the shared

memory. The secondary storage system stores the differential bitmap per URz secondary data volume in

the shared memory. When a URz pair is suspended, the tracks which contain the following journal are

marked in the differential bitmap as modified (to be copied during the resume pair operation):

The journal data that were created by the primary storage system but not yet sent to the secondary

storage system.
After marking these primary data volume tracks as modified, the primary storage system discards

these journal data.

The journal data that were sent to the secondary storage system but not acknowledged by the

secondary storage system.

50