Setting up remote copy connections, 9 urz remote copy connection configuration – HP StorageWorks XP Remote Web Console Software User Manual

Page 65

Advertising
background image

6.

HP Representative: Install the URz remote copy connections between the primary storage

system(s) and secondary storage system(s). This hardware (optical fibre cables, switches, etc.) is

supplied by the user.
See “

Setting up Remote Copy Connections

” on page 65 for remote copy configurations. Distribute

the paths between different storage clusters and switches to provide maximum flexibility and

availability. The logical paths between the primary storage system and secondary storage system

must be separate from the logical paths between the host and secondary storage system.

Setting up Remote Copy Connections

Figure 9

on page 65 shows the remote copy connection configurations for URz operations. The primary

storage system and secondary storage system of each URz pair must be connected via optical fiber

cables. If you use multimode shortwave optical fiber cables, fibre cables up to 1.5 km in length and

up to two switches are required for distances greater than 0.5 km. If you use single-mode long wave

optical fiber cables, fibre cables up to 30 km in length and up to two switches are required for distances

greater than 10 km. URz operations can be performed at distances of up to 30 km (18.6 miles) using

standard single-mode long wave support. For further distance, the channel extender connections are

required. URz operations can be performed at distances of up to 30 km (18.6 miles) using standard

single-mode long wave support. For distances greater than 43 km (26.7 miles), approved channel

extender products and telecommunications lines are required.

MCU/RCU

MCU/RCU

RCU/MCU

RCU/MCU

Shortwave: 1.5 km

Shortwave: 0.5 km

Switch

ATM telecommunications line

Optical fiber cables

Channel extender

Multimode shortwave optical fiber cables up to 0.5 km
Multimode longwave optical fiber cables up to 10 km

Max. 2 switches connection

Longwave: 10 km

MCU/RCU

RCU/MCU

RCU/MCU

MCU/RCU

Longwave:30 km

Max. 2 switches connection

MCU/RCU

RCU/MCU

MCU/RCU

Unrestricted distance

Figure 9 URz Remote Copy Connection Configuration

The remote copy connection between primary storage system and secondary storage system provides

three different configurations:

Direct connection (see

Figure 10

on page 66),

• Switch connection (see

Figure 11

on page 66),

• Extender connection (see

Figure 12

on page 66).

* To set ports, use LUN Manager and set port topology to: Fabric off, FC-AL.

Hitachi Universal Replicator for z/OS user guide for XP12000/XP10000 Disk Arrays and SVS 200

65

Advertising
This manual is related to the following products: