Urzremoteconsole software, Host i/o time-stamping function, Error reporting communications (erc) – HP StorageWorks XP Remote Web Console Software User Manual

Page 29: Urz remote console software

Advertising
background image

secondary storage system issues a "read journal" command to the primary storage system, and then the

RCU target port at the primary storage system sends journal data to the secondary storage system in

response to the "read journal" command.
Any fibre-channel interface port of the XP disk array can be configured as an initiator port. The initiator

ports cannot communicate with the host processor channels. The host channel paths must be connected to

the fibre-channel interface port other than the initiator port.

NOTE:

Two or more initiator ports must be configured before you can add the secondary storage systems and

create the URz volume pairs.

The fibre-channel interface ports that are assigned for the RCU target ports can be connected to the

host channel paths via the fibre-channel switch.
See

Configuring Port Attributes

on page 112Configuring Port Attributes for the information on configuring

host interface port.

URz Remote Console Software

XP disk array Storage Navigator Java applet program product includes URz for the XP disk array. The XP

disk array Storage Navigator software communicates with the SVP of each XP disk array via defined

TCP/IP connections. .
The Storage Navigator PC at the primary site must be attached to the primary subsystem. You should

also attach a Storage Navigator PC at the secondary site to all secondary subsystems. Having a

Storage Navigator PC at the secondary site enables you to change the URz parameter of the secondary

subsystem and access the URz secondary data volume (e.g. for the maintenance of media). If you need

to perform URz operations in the reverse direction from the secondary site to the primary site (e.g.,

disaster recovery), the XP disk array URz software simplifies and expedites this process.

NOTE:

If the XP Disk Array Storage Navigator remote console PC is not installed, please contact your HP

representative for information on URz configuration services.

Host I/O Time-Stamping Function

If you plan to establish URz journal groups, the I/O time-stamping function must be installed on the

host processor at the primary site. The I/O time-stamp, which is provided by MVS DFSMSdfp, is the

same time-stamp that is used by Compatible XRC pairs. The I/O time-stamping function should also be

installed on the host processor at the secondary site, so that time-stamps can be used when copying

data in the reverse direction.
If the system at the primary and/or secondary site consists of several CPU complexes, a SYSPLEX timer is

required to provide a common time reference for the I/O time-stamping function.

Error Reporting Communications (ERC)

Error reporting communications (ERC), which transfers information between host processors at the

primary and secondary sites, is a critical component of any disaster recovery effort. You can configure

ERC using channel-to-channel communications, NetView technology, or other interconnect technologies,

depending on your installation requirements and standards. Neither URz nor the URz remote console

software provides ERC between the primary and secondary sites.
When URz is used as a data migration tool, ERC is recommended but is not required. When URz is used

as a disaster recovery tool, ERC is required to ensure effective disaster recovery operations. When a URz

pair is suspended due to an error condition, the primary storage system generates sense information

Hitachi Universal Replicator for z/OS user guide for XP12000/XP10000 Disk Arrays and SVS 200

29

Advertising
This manual is related to the following products: