Appendix A. System Event Logging

A-2

ATLAS 800 PLUS User Manual

61200226L1-1

Table A-1.

Source: System

Event

Category

Console Log

String

Front Panel

Display

System Cold Start – generated 5 seconds
after the completion of system initializa-
tion.

Normal

Cold Start

COLD START

SNMP Authentication Failure – generated
if the ATLAS receives an SNMP request
from an SNMP manager defined in the
ATLAS SNMP Communities list but with a
community name that does not match the
community name defined in the SNMP
Communities list.

Info

SNMP Authenti-
cation Failure

AUTHEN FAIL

Module removed or not responding

Warning

Module Not
Responding

MODULE OUT -A

Module found

Information

Module Found

MODULE FOUND

Console login failure – three consecutive
login attempts were attempted and failed

Minor

Login Failure

LOGIN FAILURE

An ATLAS 800 configuration file was
loaded into the system and was activated

Critical

System Configu-
ration Uploaded

CONFIG
UPLOADED

The internal system temperature is too high

Critical

Internal Tempera-
ture Warning

TEMP WARN -A

The internal system temperature has
returned to norma

lCritical

Internal Tempera-
ture Warning
Cleared

TEMP WARN -I

The primary power supply is present but is
not operating properly

Critical

Main Power Sup-
ply Failure

PS1 WARNING -A

The primary power supply is operating
properly or has been removed

Critical

Main Power Sup-
ply Failure
Cleared

PS1 WARNING -I

The backup power supply is present but is
not operating properly

Critical

Backup Power
Supply Failure

PS2 WARNING -A

The backup power supply is operating
properly or has been removed

Critical

Backup Power
Supply Failure
Cleared

PS2 WARNING -I