Atlas, Controller t1/pri submenu items – ADTRAN ATLAS 800PLUS User Manual

Page 77

Advertising
background image

Chapter 5. Using the Terminal Menu

61200226L1-1

ATLAS

_

800

PLUS

User Manual

5-25

Empty
The system controller has not detected the presence of a module in the sys-
tem, nor has a module been manually enabled for this option slot.

Offline
The modules is installed but has been taken Offline by a user. The module is
still responding to controller polls.

Offline/No Response:
The module is installed but has been taken Offline by a user. The module is
not responding to polls.

Rev
Read security: 5
Displays the hardware revision of the ATLAS

_

800

PLUS

.

ATLAS

_

800

PLUS

Controller T1/PRI Submenu Items

The Modules/Menu submenu provides access to commands that allow you to
review the status of various options, change the configuration for general param-
eters, and initiate tests. This section only describes the menu options for the T1/
PRI controller port (the ATLAS

_

800

PLUS

base unit). For details on menu options

for individual modules, refer to the appropriate module manuals.

Controller Info
Read security: 5
Displays general information about the ATLAS

_

800

PLUS

Base Unit and T1/PRI

ports. The following items are read-only.

Alarm Status
Read security: 5
Displays any active alarms. These fields are read-only.

Part Num

Displays the part number of the ATLAS

_

800

PLUS

.

PLL Status
(Phase Lock Loop)

Indicates whether the clock is locked to its specific source.

This alarm...

Means this...

Prt

Displays the port number.

Loss of Signal
(LOS)

No signal detected on port interface.

Red Alarm
(RED)

Not able to frame data received on the port.
Alternately referred to as Out of Frame (OOF).

Yellow Alarm
(YELLOW)

Remote alarm indicator (RAI) being received on
port.

Blue Alarm
(BLUE)

Receiving unframed all ones from the port alarm
indicator signal (AIS).