Network connection – ADTRAN ATLAS 800PLUS User Manual

Page 31

Advertising
background image

Chapter 2. Installation

61200226L1-1

ATLAS

_

800

PLUS

User Manual

2-5

Network Connection

The two eight-position modular jacks labeled NTWK 1 and NTWK 2 provide net-
work connection. Table 2-3 on page 2-6 shows the pinout for the network connec-
tors.

The two Network Interface (NI) ports comply with the applicable ANSI and
AT&T

®

standards.

The NIs provide the following functions:

AMI or B8ZS coding

Manual line build out

D4 or ESF framing

Network performance monitoring and reporting

Test loopbacks with QRSS generation and checking

Extensive self test

Connection

The network connection is as follows:

Table 2-2. Control Out/Chain Out Pinout

PIN

NAME

DESCRIPTION

1

GND

Ground - connected to unit chassis.

Connect to GND of next unit (pin1).

2

UNUSED

3

TX DATA

Data transmitted to chained units by the ATLAS.
Connect to RX DATA of the next unit (chain in pin 3).

4

UNUSED

5

RX DATA

Data received from chained units by the ATLAS.
Connect to TX DATA of the next unit (chain in pin 5).

6,7,8

UNUSED

Connector type

(USOC) RJ-48C

Part number

AMP# 555164-2

Advertising