Chapter 4. Front Panel Operation and Menu Structure

61200226L1-1

ATLAS

_

800

PLUS

User Manual

4-5

Configuration Menu

The Config menu branch provides limited configuration control of the
ATLAS

_

800

PLUS

.

S0 System
S0) System
displays configuration options that are available for the
ATLAS

_

800

PLUS

Base Unit. Choose from Ethernet Configuration (see “Ethernet

Configuration” on page 4-5) or Chain Port Configuration (see “Chain Port Configu-
ration” on page 4-5).

Ethernet Configuration
Ethernet Configuration
allows you to create and change settings for the
10BaseT Ethernet connection.

IP Address
This is the address that uniquely identifies the ATLAS

_

800

PLUS

on a

TCP/IP network. This address is composed of four decimal num-
bers, each in the range of 0 to 255, separated by periods. This value is
set to 0.0.0.0 by default. The IP address is used for the 10BaseT Ether-
net interface. Obtain the correct IP address from your LAN adminis-
trator. Enter the IP address by entering each number followed by

Enter

to move to the next field.

You must define the IP address before attempting to use a Telnet program.

Subnet Mask
This option defines which part of a destination IP address is the Net-
work number. This address is composed of four decimal numbers,
each in the range of 0 to 255, separated by periods. This option is used
along with the ATLAS

_

800

PLUS

IP address to determine which nodes

must be reached through the default IP gateway. Enter the subnet
mask address by entering each number followed by

Enter

to move to

the next field.

Def Gateway
This option allows you to define or change the default gateway. You
will need a default gateway if the LAN contains multiple segments.
This address is composed of four decimal numbers, each in the range
of 0 to 255, separated by periods. This value is set to 0.0.0.0 by
default. Contact your LAN administrator for the appropriate address.
Enter the default gateway address by entering each number followed
by

Enter

to move to the next field.

Chain Port Configuration
The Chain Port menu option modifies selected items in its menu branch.

Baud Rt
This option displays and changes the baud rate. The supported baud
rates for the chain port include 2400 and 9600 bps. If Type is set to

Dial

, make sure this field matches the modem baud rate.