Chapter 5. Using the Terminal Menu

5-26

ATLAS

_

800

PLUS

User Manual

61200226L1-1

DS0 Status
Read security: 5
Indicates usage on a DS0 basis for each port. These options are read-only.

Sig Status
Read security: 5
Indicates signaling of all 24 DS0s. The A/B bits for Rx and Tx DS0s are shown for
each port.

Performance: Current
Write security: 4; Read security: 5
The performance fields – either current, 15 minute total, or 24 hour total – provide
status on key performance measures as specified in ANSI T1.403 and AT&T
TR54016 for each of the four T1/PRI ports. All of these options (except

CLR

) are

read-only. The parameters monitored include the following:

D Channel Sync
(D-Chan)

HDLC framing is operational on PRI D channel.
This indication only applies when operating in PRI
mode.

Receive Level
(Rx Level)

Indicates the strength of the signal received on the
port.

DS0 status...

Means this...

*

Inactive

A

Active call on this DS0

D

Active D Channel DS0

M

Maintenance DS0

N

Dedicated DS0

O

Off hook Detected

R

Ringing Detected

Field... Provides this status information...

Prt

Displays the port number.

CLR

Clears information for the selected port. Press Enter when
the cursor is over this field to clear the data.

ES

Errored Seconds. An ES is a second with one or more error
events OR one or more Out Of Frame events OR one or
more Controlled Slips.

BES

Bursty Errored Seconds. A BES is a second with more than
one, but less than 320 error events.

SES

Severely Errored Seconds. An SES is a second with 320 or
more error events OR one or more Out Of Frame events.

SEFS

Severely Errored Frame Seconds.

LOFC

Loss of Frame Count.

CSS

Controlled Slip Seconds.

This alarm...

Means this...

Advertising